A fault in the AdBlue system on a truck can cause a loss of engine power, limp mode, and even a kilometre countdown to a power limit or a start lock. It is worth finding the cause as soon as possible.
We come to the breakdown, a car park, a fuel station or a motorway. We check the AdBlue system and the SCR system with a JALTEST diagnostic tester. If the fault allows it, we do the repair on site.
Before we set off, we often ask for a photo of the message on the dashboard or of the fault code. That makes it easier to judge the problem in advance and to prepare for the repair.
Problems with the AdBlue system can show in different ways. Drivers most often notice:
The SCR system reduces the amount of harmful nitrogen oxides in the exhaust. The pump feeds AdBlue fluid from the tank to the injector, which sprays it into the exhaust. The SCR catalyst then helps to cut the harmful substances, and the NOx sensors check that the system is working properly.
If one of these parts stops working, a fault can appear on the dashboard, and the engine can go into limp mode and lose power.
A failure of the AdBlue pump or of the dosing module can cause faults linked to fluid pressure. You may then notice that AdBlue is not drawn properly from the tank, and the truck loses power and goes into limp mode.
A failed NOx sensor can cause faults linked to the exhaust and send the engine into limp mode. The truck may also start to use too much AdBlue, or the fluid may stop leaving the tank. During diagnostics we check the sensor readings and find which sensor is wrong, the one before the catalyst or the one after it.
AdBlue crystallisation shows as a white deposit that can block the injector, the pipes or other parts of the system. If you see that deposit, do not try to take the installation apart yourself. We first check where the problem formed and how heavy the contamination is. We then judge whether cleaning the system is enough, or whether the damaged part has to be replaced.
At low temperatures the AdBlue fluid can freeze. Heaters in the tank, the pump and the pipes help to thaw it. If the fault message is still there after the engine has warmed up, we can check whether the heaters are working properly. From that we find the cause.
It depends on the message on the dashboard and on whether the truck has already started to limit engine power. If only the AdBlue warning light is on and there are no other symptoms, you can sometimes drive carefully to the nearest safe car park. If limp mode appears, or a kilometre countdown to a power limit, do not put off the diagnosis.
We start by connecting the JALTEST diagnostic computer. We check the stored faults and the sensor readings, and the temperature and pressure in the system. If needed, we also run a function test of the AdBlue system. That shows the exact cause of the failure and which parts need repair or replacement.
If the fault can be repaired on site, we take on the damaged parts of the AdBlue system at the truck, such as the pump, the dosing module or the pipes, and where the injector or the NOx sensor is the cause, AdBlue injector replacement or NOx sensor replacement is done on the truck as well. The scope of the repair depends on the kind of failure and on whether the needed parts are available. After the repair we check that the system works, carry out the settings that are needed, and clear the faults.
When an AdBlue fault comes together with other codes, we run a full truck diagnostics. If the cause is on the fuel-injection side, the fuel system may need repair.
We do not remove AdBlue and we do not switch it off. Switching off the SCR system is against the rules in the EU and can mean trouble at a roadside check (for example ITD in Poland, BAG in Germany), so we repair the system so that it works to the standard.
A kilometre countdown to a power limit? Call +48 796 000 287.
The price depends on what exactly has failed, which parts are needed, and where the truck is. We give a preliminary quote before the work starts. It covers the parts and the labour. How we calculate it is set out in the price list.
| Repair at the car park | Towing to a workshop abroad | |
|---|---|---|
| Truck | stays where it stopped | goes on a recovery truck to a workshop |
| Parts | from a wholesaler, straight away | often to order |
| Conversation | in Polish, in English | usually in the language of the country |
| Cost | a preliminary quote before the repair | towing, the repair and standing time |
We repair AdBlue systems on MAN, DAF, Scania, Volvo, Renault and Mercedes-Benz trucks, and on Iveco. We work on vehicles with Euro 5 and Euro 6 engines that have an SCR system.
Yes, we repair AdBlue on trucks in Germany and in other countries in Europe. Country pages: Netherlands, Belgium, Denmark, France, Italy, Switzerland, Austria, Czechia, Slovakia, Slovenia, Hungary, Romania.
When the AdBlue tank is empty, the computer warns the driver, then limits engine power, and after a time it can block the next start. If the fault is still there after you add AdBlue, a diagnosis is needed.
It depends on the message on the dashboard and on whether engine power is already limited. If a kilometre countdown to a power limit has started, it is best to contact a workshop before you drive on. Call us and say what the computer shows, and we will help you judge the situation.
The price depends on the cause of the failure, the parts needed, and where the truck is standing. Before the repair starts we give a quote that covers the parts and the labour.
We do not switch the AdBlue system off and we do not remove it. We diagnose it and repair it so that it works properly and within the rules.
Most often there is an exhaust-emissions fault, and the engine can go into limp mode and lose power. Sometimes the AdBlue use is also wrong: the fluid does not leave the tank, or more of it is used than usual. To confirm the fault, the sensor readings have to be checked during diagnostics.
Tel. +48 796 000 287, SMS and WhatsApp +48 502 486 186. You can also report a breakdown.